Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biotechnol J ; 18(7): e2300004, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37100765

RESUMO

The development of functional blood vessels is today a fundamental pillar in the evaluation of new therapies and diagnostic agents. This article describes the manufacture and subsequent functionalization, by means of cell culture, of a microfluidic device with a circular section. Its purpose is to simulate a blood vessel in order to test new treatments for pulmonary arterial hypertension. The manufacture was carried out using a process in which a wire with a circular section determines the dimensions of the channel. To fabricate the blood vessel, cells were seeded under rotary cell culture to obtain a homogeneous cell seeding in the inner wall of the devices. This is a simple and reproducible method that allows the generation of blood vessel models in vitro.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Técnicas de Cultura de Células
2.
Bioengineering (Basel) ; 10(2)2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36829677

RESUMO

Post-surgical chemotherapy in pancreatic cancer has notorious side effects due to the high dose required. Multiple devices have been designed to tackle this aspect and achieve a delayed drug release. This study aimed to explore the controlled and sustained local delivery of a reduced drug dose from an irinotecan-loaded electrospun nanofiber membrane (named TARTESSUS) that can be placed on the patients' tissue after tumor resection surgery. The drug delivery system formulation was made of polycaprolactone (PCL). The mechanical properties and the release kinetics of the drug were adjusted by the electrospinning parameters and by the polymer ratio between 10 w.t.% and 14 w.t.% of PCL in formic acid:acetic acid:chloroform (47.5:47.5:5). The irinotecan release analysis was performed and three different release periods were obtained, depending on the concentration of the polymer in the dissolution. The TARTESSUS device was tested in 2D and 3D cell cultures and it demonstrated a decrease in cell viability in 2D culture between 72 h and day 7 from the start of treatment. In 3D culture, a decrease in viability was seen between 72 h, day 7 (p < 0.001), day 10 (p < 0.001), 14 (p < 0.001), and day 17 (p = 0.003) as well as a decrease in proliferation between 72 h and day 10 (p = 0.030) and a reduction in spheroid size during days 10 (p = 0.001), 14 (p < 0.001), and 17 (p < 0.001). In conclusion, TARTESSUS showed a successful encapsulation of a chemotherapeutic drug and a sustained and delayed release with an adjustable releasing period to optimize the therapeutic effect in pancreatic cancer treatment.

3.
J Photochem Photobiol ; 11: 100138, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35958025

RESUMO

SARS-CoV-2 is responsible for the COVID-19 pandemic, which has caused almost 570 million infections and over six million deaths worldwide. To help curb its spread, solutions using ultraviolet light (UV) for quick virus inactivation inside buildings without human intervention could be very useful to reduce chances of contagion. The UV dose must be sufficient to inactivate the virus considering the different materials in the room, but it should not be too high, not to degrade the environment. In the present study, we have analyzed the ability of a 254 nm wavelength UV-C lamp to inactivate dried samples of SARS-CoV-2 exposed at a distance of two meters, simulating a full-scale scenario. Our results showed that virus inactivation was extremely efficient in most tested materials, which included plastic, metal, wood, and textile, with a UV-C exposure of only 42 s (equivalent to 10 mJ/cm2). However, porous materials like medium density fibreboard, were hard to decontaminate, indicating that they should be avoided in hospital rooms and public places.

4.
Nanomedicine ; 39: 102462, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34592426

RESUMO

Mimicking the diffusion that drugs suffer through different body tissues before reaching their target is a challenge. In this work, a versatile membrane-based microfluidic platform was developed to allow for the identification of drugs that would keep their cytotoxic properties after diffusing through such a barrier. As an application case, this paper reports on a microfluidic device capable of mimicking the diffusion that free or encapsulated anticancer drugs would suffer in the intestine before reaching the bloodstream. It not only presents the successful fabrication results for the platform but also demonstrates the significant effect that the analyzed drugs have over the viability of osteosarcoma cells. This intestine-like microfluidic platform works as a tool to allow for the identification of drugs whose cytotoxic performance remains effective enough once they enter the bloodstream. Therefore, it allows for the prediction of the best treatment available for each patient in the battle against cancer.


Assuntos
Antineoplásicos , Técnicas Analíticas Microfluídicas , Neoplasias , Antineoplásicos/farmacologia , Difusão , Humanos , Dispositivos Lab-On-A-Chip , Microfluídica/métodos
5.
Bioengineering (Basel) ; 8(6)2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34199965

RESUMO

The use of lipid nanoparticles as biodegradable shells for controlled drug delivery shows promise as a more effective and targeted tumor treatment than traditional treatment methods. Although the combination of target therapy with nanotechnology created new hope for cancer treatment, methodological issues during in vitro validation of nanovehicles slowed their application. In the current work, the effect of methotrexate (MTX) encapsulated in different matrices was evaluated in a dynamic microfluidic platform. Effects on the viability of osteosarcoma cells in the presence of recirculation of cell media, free MTX and two types of blank and drug-containing nanoparticles were successfully assessed in different tumor-mimicking microenvironments. Encapsulated MTX was more effective than the equal dose free drug treatment, as cell death significantly increased under the recirculation of both types of drug-loaded nanoparticles in all concentrations. In fact, MTX-nanoparticles reduced cell population 50 times more than the free drug when 150-µM drug dose was recirculated. Moreover, when compared to the equivalent free drug dose recirculation, cell number was reduced 60 and 100 points more under recirculation of each nanoparticle with a 15-µM drug concentration. Thus, the results obtained with the microfluidic model present MTX-lipid nanoparticles as a promising and more effective therapy for pediatric osteosarcoma treatment than current treatment options.

6.
Biomicrofluidics ; 13(4): 044105, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31372193

RESUMO

Highly migratory cancer cells often lead to metastasis and recurrence and are responsible for the high mortality rates in many cancers despite aggressive treatment. Recently, the migratory behavior of patient-derived glioblastoma multiforme cells on microtracks has shown potential in predicting the likelihood of recurrence, while at the same time, antimetastasis drugs have been developed which require simple yet relevant high-throughput screening systems. However, robust in vitro platforms which can reliably seed single cells and measure their migration while mimicking the physiological tumor microenvironment have not been demonstrated. In this study, we demonstrate a microfluidic device which hydrodynamically seeds single cancer cells onto stamped or femtosecond laser ablated polystyrene microtracks, promoting 1D migratory behavior due to the cells' tendency to follow topographical cues. Using time-lapse microscopy, we found that single U87 glioblastoma multiforme cells migrated more slowly on laser ablated microtracks compared to stamped microtracks of equal width and spacing (p < 0.05) and exhibited greater directional persistence on both 1D patterns compared to flat polystyrene (p < 0.05). Single-cell morphologies also differed significantly between flat and 1D patterns, with cells on 1D substrates exhibiting higher aspect ratios and less circularity (p < 0.05). This microfluidic platform could lead to automated quantification of single-cell migratory behavior due to the high predictability of hydrodynamic seeding and guided 1D migration, an important step to realizing the potential of microfluidic migration assays for drug screening and individualized medicine.

7.
Biosens Bioelectron ; 123: 237-243, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-30224287

RESUMO

Development of new targeted therapies is a challenge in the battle against cancer. Although a variety of treatments is currently available, there is no technique for rapidly evaluating the response of cancer patients to the drug. In this work, a microfluidic platform for the real-time simultaneous analysis of the success rate of different nanoparticle based chemotherapeutic drugs is presented. Based on a previous planar chamber and a reported sensitivity enhancing strategy, linear and cross shape microstructures were integrated into the chamber dome of the microfluidic polydimethylsiloxane and glass platform in order to provide a higher fluid mixing and treatment-cell interaction. Several methotrexate (MTX) based treatments (free MTX, MTX loaded Lecithin-PVA nanoparticles, MTX loaded Lecithin-Tween 80 nanoparticles) as well as their respective controls (cell media and both blank nanoparticles) were recirculated through the microchamber over an osteosarcoma cell monolayer. These nanovehicles reduced cell population to less than 20% (LEC-PVA nanoparticles) and 2.3% (LEC-Tween nanoparticles), demonstrating that nanoparticles are a promising target therapy for cancer treatment. Moreover, microstructured platforms demonstrated a higher efficacy in the drug-screening process: due to the liquid folding a higher amount of nanoparticles was internalized by the cells and, therefore, results were observed faster. In fact, the time required to reduce cell viability to the half was nearly a 75% faster. Furthermore, this microfluidic platform offers the capability to test up to five different drugs simultaneously, making it a powerful tool to evaluate the effect of multiple drugs and determine the most effective and personalized treatment.


Assuntos
Técnicas Biossensoriais , Avaliação Pré-Clínica de Medicamentos/métodos , Microfluídica/métodos , Neoplasias/tratamento farmacológico , Linhagem Celular Tumoral , Sobrevivência Celular/efeitos dos fármacos , Humanos , Metotrexato/farmacologia , Metotrexato/uso terapêutico , Nanopartículas/química , Medicina de Precisão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...